Szczegółowy opis produktu
Product Name: EKRV Series Cooling Only Digital Multi-connected Central Air Conditioner Cooling Capacity(kW): 10kW-90kW
Refrigerant Type: R22 Range of Sound Level dB(A): 59-63
High Light:

vrf technology air conditioner

,

air conditioner hvac systems

 

EKRV Series Cooling Only Digital Multi-connected Central Air Conditioner

 

Parameter

 

Model   EKRV040A EKRV050A EKRV060A EKRV050A EKRV060A EKRV070A
Cooling capacity kW 10 12.5 14.5 12.5 15 18.5
Input power Cooling kW 3.4 4.2 4.9 4.2 4.9 5.8
Power supply   220V~/50Hz 380V/3N~/50Hz
Input current Cooling A 15.5 19.1 22.3 7.9 9.1 11.7
Connector size Liquid pipe mm 9.52 9.52 9.52 9.52 9.52 9.52
Gas pipe mm 19.05 19.05 19.05 19.05 19.05 22.23
Unit weight kg 115/120 120/125 124/129 120/125 124/129 130/135
Noise dB(A) 59 59 60 59 60 61
Refrigerant type   R22
Dimensions (W x D x H) mm 970x355x1050 970x355x1255 970x355x1050 970x355x1255

 

Model  

EKRV

080A

EKRV

100A

EKRV

120A

EKRV

140A

EKRV

160A

EKRV

180A

EKRV

200A

Cooling capacity kW 25.0 28 33.5 40.0 45.0 50.5 56.0
Input power Cooling kW 7.7 8.4 10.2 12.4 14.1 14.8 16.8
Power supply   380V/3N~/50Hz  
Rated current Cooling A 15.0 16.6 19.6 23.9 26.3 29.6 34.4
Connector size Liquid pipe mm 12.70 12.70 15.88 15.88 15.88 15.88 15.88
Gas pipe mm 28.6 28.6 28.6 34.9 34.9 34.9 34.9
Unit weight kg 275/290 285/300 290/305 335/350 345/360 520/550 560/590
Noise dB(A) 56 57 60 60 60 61 61
Refrigerant type   R22  
Dimensions (W x D x H) mm 990x840x1840 1290x840x1841 1990x840x1840  1990x840x1840

 

Model  

EKRV220A

EKRV240A

EKRV260A EKRV280A EKRV300A EKRV320A
Cooling capacity kW 61.5 68 73.5 78.5 85.0 90.0
Input power Cooling kW 18.6 20.6 22.6 24.3 26.5 28.2
Power supply   380V/3N~/50Hz
Rated current Cooling A 36.4 40.1 42.4 45.3 47.0 50.4
Connector size Liquid pipe mm 19.05 19.05 19.05 19.05 19.05 19.05
Gas pipe mm 38.1 38.1 41.3 41.3 41.3 41.3
Equalizer pipe size mm -- -- 9.52 9.52 9.52 9.52
Unit weight kg 560/590 570/600 625/655 635/665 680/710 690/720
Noise dB(A) 62 62 62 62 62 63
Refrigerant type   R22
Dimensions (W x D x H) mm 1990x840x1840 2580x840x1840 2580x840x1840

 

Description:

 

1. ide Capacity Regulation Range and Precise Ambient Temperature ControlBy using a PWM valve to control the time ratio of unloading and loading status, the digital scroll compressor can continuously regulate the capacity within a range of 10%–100%, increasing the precision of capacity regulation and the stability of indoor temperature, and providing differentiated air conditioning experience to customers.

 

2. Low Energy Consumption

The unit boasts an outstanding IPLV(C) (refrigerating coefficient of performance). The full series of units features an IPLV(C) that is far higher than national standard energy efficiency level 1.

 

3. Brushless DC motor (optional)

Fans of outdoor units can be regulated at 32 levels based on load changes, improving efficiency and reducing noise.

 

4. Supercooling Technologies

• Enlarges the condenser of the outdoor unit to implement level-1 supercooling, and then uses an efficient supercooler to implement level-2 supercooling.
• Enhances the cooling capability of the unit and improves the efficiency of the unit.
• Reduces the pressure loss when the refrigerant is circulated in the pipe, rationally allocating the ultra-long accessory pipe and refrigerant.

 

5. Intelligent Defrosting Technologies

The unit intelligently determines the best time for defrosting based on the ambient temperature, evaporating pressure, suction temperature, and defrosting cycle to ensure that frost is effectively removed in a timely manner. After frost is removed, the unit quickly regulates the indoor temperature to the set one based on the rapid start technologies that are used in fixed-capacity compressors, and by adjusting the opening of electronic expansion valve through a microcomputer.

 

6. No Power Consumption Resulting from Power Conversion

Digital multi-connected systems do not use electronic components with variable frequency speed regulation, and therefore no power consumption is caused from power conversion and the loss caused by
the heat resulting from transducer operation is reduced.

 

7. The hermetic mechanical room helps prolong the service life and isolate noise.

• Effectively protects controllers and key valves against sunlight and rain, ensuring the service life.
• The hermetic compressor installation cavity effectively shields the noise resulting from compressor operation.
• The advanced heat exchanger structure requires reserved space for air return and maintenance access on only two surfaces.

The unit uses an electronic expansion valve with 4000-step capacity regulation to increase the precision of superheat degree control (liquid level control), enhance the operation security, and improve energy saving.

 

8. Reliable and Stable

EKRV series digital multi-connected central air conditioners use mechanical devices to regulate the capacity without requiring complex variable-frequency controllers, increasing the stability and reliability of
the unit. EKRV Series Digital Multi-connected Central Air Conditioner vs Variable-Frequency Air Conditioner

  Typical Variable- Frequency System EKRV Digital System
Microprocessor Multiple Single
Liquid shunting system Required Not required
Electromagnetic dampening Required Not required
Dehumidification capability Moderate Excellent
Capability regulation range 30%~100% 10%~100%

 

9. Wide operation range

The unit features an advanced cooling system design and has undergone strict system matching and test, providing strong cooling/heating capabilities. EKRV series digital multi-connected central air-conditioning units can generate cooling result in hot weather with a temperature of 54°C, and generate heating result in cold weather with a temperature of -15°C.

 

Applications

hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

factories, school supermarkets and so on.

Szczegóły kontaktu
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Osoba kontaktowa: Mr. LENG Zhengliang

Tel: +86 13828797702

Faks: 86-0769-83622528

Wyślij zapytanie bezpośrednio do nas (0 / 3000)

Inne produkty